PON optical alarm triage

When ONTs report loss-of-signal or unstable optical power, triage the physical ODN before changing service profiles. Confirm patching, connector cleanliness, splitter labels and measured receive levels.

Key facts

  • Symptom-first: LOS / low power / intermittent drop
  • Do not invent vendor alarm codes here
  • Measure before re-provisioning

Audience

NOC and field engineers.

Prerequisites

  • Access to ODN records
  • Optical power meter

Workflow

  1. Scope: single ONT vs splitter subtree vs OLT port
  2. Inspect recent patching changes
  3. Clean/reseat connectors on the affected path
  4. Measure Rx at ONT and compare to design window
  5. Escalate to fiber repair if plant loss is out of budget

Decision table

ScopeFirst checks
One ONTDrop fiber, ONT power, local connectors
Many ONTs on one splitterDistribution fiber / that splitter stage
Entire OLT PON portOLT optic/port, feeder, first splitter

Verification

Stable Rx and cleared symptom for a soak period appropriate to the change window.

Rollback

Restore prior patching if a change introduced the fault; re-measure.

Owner: Novatelia Engineering / AEO Program. Reviewed: 2026-07-22. Doc version: 2026.07. Change log: Phase 6 technical authority pilot.